New
-
A new data type, Arrays, has been added for the FBD language.
-
Added the ability to configure the thickness and color of the focus frame.
-
For the "Menu" element, a new toggleable property "In Focus by Default" has been added, which automatically sets focus on this element when the screen is opened.
-
Added a "Loading screen" feature, allowing you to change the image displayed on second-generation devices when they are powered on.
-
In the variable table, the "Show nested variables" setting now affects the variable count in the catalog.
-
ALP now saves and transfers the structure of network variable catalogs, which is used by ToolPro when building the parameter tree.
Firmware-Updates
-
The devices PR110, PR114, and PR-KIT have been removed from the list of supported devices.
-
Firmware for PR103 v1.12.0 devices:
-
Added support for arrays in FBD.
-
Fixed operation over RS-485 in 7n2 mode.
-
Firmware for PR205 and PR225 v1.11.0 devices:
-
Added support for arrays in FBD.
-
Fixed operation over RS-485 in 7n2 mode.
-
Added support for custom startup images.
-
Added support for controlling focus frame color and thickness.
-
Added support for the "In Focus by Default" property for the "Menu" control.
-
Fixed a bug causing device reboots due to incorrect memory calculation for visualization controls with rounded corners.
-
Firmware for PR200, PR102, PR100 [M02], SMI200 v2.77, and PR100 v3.12 devices:
-
Added support for arrays in FBD.
-
Fixed operation over RS-485 in 7n2 mode.
Fixed:
-
Corrected the title of the display form properties panel for second-generation devices.
-
Fixed an error that occurred when calling the CD32 and DC32 functions if their argument was outside the valid Int32 range.
-
Fixed an error where changing the text of the "Text" element for second-generation devices was not recognized by the program as a project change.
-
Fixed an error where the analog input parameters tab was not updated after reading values.
-
Fixed incorrect display of input pins on the diagram for functions written in ST.
-
Fixed data offset issue during group polling by second-generation devices when a status variable was linked.
-
Fixed an error where name checking in ST was case-sensitive.
-
Fixed an error that occurred when switching to the slave variables tab in the variable table for second-generation devices.
-
Fixed incorrect rounding of float variables in simulation mode.
-
Fixed an error where exporting second-generation devices to an OPC server resulted in an incorrect byte and register order being transmitted.