Bug Fixes
-
The firmware for PR205, PR225 and PR205[M02] devices included with ALP has been updated from version 1.11.4 to 1.12.1.
ALP build 3.2.385 included firmware version 1.11.4 instead of firmware version 1.12.0 stated in the changelog.
New
-
Added the ability to automatically save a project at user-specified intervals.
-
The ability to group transfer variables to the canvas from the variables panel has been implemented.
-
Added a custom grid for the second-generation instrument visualization editor.
-
Added the ability to collapse and expand directories in the variables panel.
-
Added a new visualization control for second-generation devices - "Pointer Indicator".
-
The maximum number of characters in variable names is limited when importing/exporting a variable table, as well as when duplicating variables.
-
Automatic restart of the application after changing the language has been implemented.
Updates
-
Firmware for PR205, PR225 and PR205[M02] devices v1.12.0:
-
The "Pointer Indicator" control is supported.
-
Fixed AI PR205[M02] indication when the sensor is broken in resistance measurement mode.
-
Fixed blocking of editing network parameters via the system menu.
-
Corrected images for calibrating analog outputs for PR225.
-
Fixed the operation of relays 9–12 for PR205.24.x.2.
-
Fixed incorrect display of measurement units for analog inputs.
Bug Fixes
-
Fixed an error that occurred when attempting to open the device settings window after changing the target platform to a platform without Ethernet, if the original project had a Master device with the "Ethernet" interface type.
-
Fixed incorrect behavior of the properties panel when changing the target platform with the boot image window open.
-
Fixed a bug due to which, after changing the target platform from one second-generation device to another, which has a number of discrete inputs less than the first device, with a non-zero input inversion, it was impossible to open the project after saving.
-
Fixed an error that occurred after changing the target platform to a platform without Ethernet, if the source project had variables bound to connection parameters with akYtec Cloud.
-
Fixed a bug that caused a dialog box to briefly appear after entering a constant value.
-
The windows that appear when deleting variables that have links have been brought into a unified appearance.
-
Fixed an error that occurred after attempting to undo the action of deleting the "PID_REG" macro after changing the platform from a device that supports this macro to a device that does not support it.
-
Fixed a bug that allowed inserting service characters into text parameters akYtec ALP.
-
Fixed a bug that caused the variable selection in the variables panel to disappear after changing its type to an array.
-
Fixed a bug that caused the decimal place setting to be reset after binding a variable to second-generation instrument visualization elements.
-
Fixed a bug where canceling a change to the target platform in a PR225 project would cause the physical button to disappear from the visualization editor.
-
Fixed a bug where when changing the target platform from PR205/PR225 to PR103, the button for calling the display simulation remained in the interface.
-
Fixed a bug where binding two or more array elements to a poll status/polling command in Modbus Master would cause the project to fail to compile.
-
Fixed an error that occurred when installing akYtecALP with the "Install .NET6 SDK to create a replication wizard for Linux" option checked.