Version History of akYtec ALP

27.10.2026

3.2.386

Bug Fixes

  1. The firmware for PR205, PR225 and PR205[M02] devices included with ALP has been updated from version 1.11.4 to 1.12.1. ALP build 3.2.385 included firmware version 1.11.4 instead of firmware version 1.12.0 stated in the changelog.
16.10.2026

3.2.385

New

  1. Added the ability to automatically save a project at user-specified intervals.
  2. The ability to group transfer variables to the canvas from the variables panel has been implemented.
  3. Added a custom grid for the second-generation instrument visualization editor.
  4. figure
  5. Added the ability to collapse and expand directories in the variables panel.
  6. Added a new visualization control for second-generation devices - "Pointer Indicator".
  7. figure
  8. The maximum number of characters in variable names is limited when importing/exporting a variable table, as well as when duplicating variables.
  9. Automatic restart of the application after changing the language has been implemented.

Updates

  1. Firmware for PR205, PR225 and PR205[M02] devices v1.12.0:
    • The "Pointer Indicator" control is supported.
    • Fixed AI PR205[M02] indication when the sensor is broken in resistance measurement mode.
    • Fixed blocking of editing network parameters via the system menu.
    • Corrected images for calibrating analog outputs for PR225.
    • Fixed the operation of relays 9–12 for PR205.24.x.2.
    • Fixed incorrect display of measurement units for analog inputs.

Bug Fixes

  1. Fixed an error that occurred when attempting to open the device settings window after changing the target platform to a platform without Ethernet, if the original project had a Master device with the "Ethernet" interface type.
  2. Fixed incorrect behavior of the properties panel when changing the target platform with the boot image window open.
  3. Fixed a bug due to which, after changing the target platform from one second-generation device to another, which has a number of discrete inputs less than the first device, with a non-zero input inversion, it was impossible to open the project after saving.
  4. Fixed an error that occurred after changing the target platform to a platform without Ethernet, if the source project had variables bound to connection parameters with akYtec Cloud.
  5. Fixed a bug that caused a dialog box to briefly appear after entering a constant value.
  6. The windows that appear when deleting variables that have links have been brought into a unified appearance.
  7. Fixed an error that occurred after attempting to undo the action of deleting the "PID_REG" macro after changing the platform from a device that supports this macro to a device that does not support it.
  8. Fixed a bug that allowed inserting service characters into text parameters akYtec ALP.
  9. Fixed a bug that caused the variable selection in the variables panel to disappear after changing its type to an array.
  10. Fixed a bug that caused the decimal place setting to be reset after binding a variable to second-generation instrument visualization elements.
  11. Fixed a bug where canceling a change to the target platform in a PR225 project would cause the physical button to disappear from the visualization editor.
  12. Fixed a bug where when changing the target platform from PR205/PR225 to PR103, the button for calling the display simulation remained in the interface.
  13. Fixed a bug where binding two or more array elements to a poll status/polling command in Modbus Master would cause the project to fail to compile.
  14. Fixed an error that occurred when installing akYtecALP with the "Install .NET6 SDK to create a replication wizard for Linux" option checked.