Updates
-
Firmware of the PRM-x.1 v1.08 expansion module:
- A firmware bug has been fixed
Bug Fixes
- A firmware bug has been fixed PRM
-
The discrete outputs and analog outputs for the PR200 and
PR102 devices have been added in the settings window of the
device
-
Copying and pasting PR200 render screens between projects has
been fixed for some users
- Fixed an error when displaying the first help page
-
A changelist page has been added, which is displayed depending
on the selected language
- The default language has been added in the installer
Updates
-
Firmware for PR103 device v1.8.2:
-
The launch of calibration via akYtec ToolPro has been
debugged
New
- The help has been updated
Updates
-
Firmware for PR103 device v1.8.1:
-
The operation of the device's flash memory has been
optimized
-
The operation of the device's file system has been
optimized
-
Firmware for PR100[M02], PR102, PR200 and SMI200 devices
v2.70:
-
Fixed reading of the registers of the number and version
of the algorithm by Modbus
Bug Fixes
-
Fixed the error of switching to simulation mode when the
"Display form" tab is open in projects for PR200 and SMI200
devices
Updates
-
Firmware for PR103 device v1.8.0:
-
ATTENTION! In the device settings, the default value of
the safe state of the digital outputs has been changed
from the value "unchanged" to "open"
-
The error of resetting the exchange status after several
requests with a timeout error has been fixed in Modbus
Master
-
Firmware of the PRM-x.1 v1.08 expansion module:
-
ATTENTION! In the device settings, the default value of
the safe state of the digital outputs has been changed
from the value "unchanged" to "open" in the projects for
PR103
-
Firmware of the PRM-x.2 v1.07 expansion module:
-
ATTENTION! In the device settings, the default value of
the safe state of the digital outputs has been changed
from the value "unchanged" to "open" in the projects for
PR103
- Fixed incorrect AI operation in discrete mode
Updates
-
New firmware versions for PR100[М02] and PR102 v2.69:
-
The operation of the device's retain memory has been
improved
Updates
-
New firmware versions for PR100[М02] and PR102 v2.68:
-
The operation of the device's retain memory has been
stabilized
Bug Fixes
- Fixed an error in simulating high-load projects
New
-
New functions added in ST:
- Copy/paste ST block between projects
-
Password protection for ST block using <Password>
tag
-
Display of function and FB descriptions, input/output
descriptions from corresponding <Description> tags
in input assistant in ST editor
-
Display of ST block description from <Description>
tag in tooltip when hovering over it on the canvas
-
Added user project protection function with file-key for PR103
devices
-
New parameters added in "Project Info - Algorithm" window:
Name, Group, Number, Version for PR103 devices
Updates
-
Firmware for PR103 device v1.7.0:
-
Supported user project protection mechanism with file-key
-
Supported project information: Name, Group, Number,
Version
-
Increased Modbus Master network memory area by 3 times:
from 64 to 192 requests for all slave devices
-
Fixed issue of data display from one slave device's
registers in other slave devices' registers
-
Fixed analog input display in NTC sensor mode during break
and short circuit. AI readings when sensor is broken:
-9999, when short-circuited: +9999
Bug Fixes
- Enabled scroll in ST editor in simulation mode
-
Allowed different Modbus functions to write to the same
register address
- Added user color saving in visualization palette
-
Added saving of the last connection mode with the device
- Reduced tooltip size on canvas